Failed Tests
hypershift_framework.go:317: Successfully created hostedcluster e2e-clusters-sthm2/node-pool-74wvl in 2m30s
hypershift_framework.go:115: Summarizing unexpected conditions for HostedCluster node-pool-74wvl
eventually.go:104: Failed to get *v1beta1.HostedCluster: client rate limiter Wait returned an error: rate: Wait(n=1) would exceed context deadline
util.go:2166: Failed to wait for HostedCluster e2e-clusters-sthm2/node-pool-74wvl to have valid conditions in 2s: context deadline exceeded
eventually.go:224: observed *v1beta1.HostedCluster e2e-clusters-sthm2/node-pool-74wvl invalid at RV 96183 after 2s:
eventually.go:227: - incorrect condition: wanted ClusterVersionProgressing=True, got ClusterVersionProgressing=False: FromClusterVersion(Cluster version is 4.20.0-0.ci-2025-05-30-142031-test-ci-op-3r5dpm91-latest)
eventually.go:227: - incorrect condition: wanted ClusterVersionSucceeding=False, got ClusterVersionSucceeding=True: FromClusterVersion
eventually.go:227: - incorrect condition: wanted ClusterVersionAvailable=False, got ClusterVersionAvailable=True: FromClusterVersion(Done applying 4.20.0-0.ci-2025-05-30-142031-test-ci-op-3r5dpm91-latest)
hypershift_framework.go:195: skipping postTeardown()
hypershift_framework.go:176: skipping teardown, already called
util.go:219: Successfully waited for kubeconfig to be published for HostedCluster e2e-clusters-sthm2/node-pool-74wvl in 25ms
util.go:236: Successfully waited for kubeconfig secret to have data in 25ms
util.go:282: Successfully waited for a successful connection to the guest API server in 0s
nodepool_machineconfig_test.go:55: Starting test NodePoolMachineconfigRolloutTest
util.go:463: Successfully waited for 1 nodes to become ready for NodePool e2e-clusters-sthm2/node-pool-74wvl-test-machineconfig in 7m7.225s
nodepool_test.go:350: Successfully waited for NodePool e2e-clusters-sthm2/node-pool-74wvl-test-machineconfig to have correct status in 45.025s
util.go:379: Failed to wait for NodePool e2e-clusters-sthm2/node-pool-74wvl-test-machineconfig to start config update in 1m0s: context deadline exceeded
eventually.go:224: observed *v1beta1.NodePool e2e-clusters-sthm2/node-pool-74wvl-test-machineconfig invalid at RV 49048 after 1m0s: incorrect condition: wanted UpdatingConfig=True, got UpdatingConfig=False: AsExpected
util.go:379: *v1beta1.NodePool e2e-clusters-sthm2/node-pool-74wvl-test-machineconfig conditions:
util.go:379: UpdatingVersion=False: AsExpected
util.go:379: ReachedIgnitionEndpoint=True: AsExpected
util.go:379: AutoscalingEnabled=False: AsExpected
util.go:379: ValidReleaseImage=True: AsExpected(Using release image: registry.build01.ci.openshift.org/ci-op-3r5dpm91/release@sha256:ef520aaa312dbd47f77499477c08b46316169e9d3061c613bd33dc60c4f9610f)
util.go:379: ValidArchPlatform=True: AsExpected
util.go:379: ReconciliationActive=True: ReconciliationActive(Reconciliation active on resource)
util.go:379: ValidMachineConfig=True: AsExpected
util.go:379: UpdatingConfig=False: AsExpected
util.go:379: ValidGeneratedPayload=True: AsExpected(Payload generated successfully)
util.go:379: UpdateManagementEnabled=True: AsExpected
util.go:379: ValidPlatformConfig=True: AsExpected(All is well)
util.go:379: AllMachinesReady=True: AsExpected(All is well)
util.go:379: AllNodesHealthy=True: AsExpected(All is well)
util.go:379: ValidTuningConfig=True: AsExpected
util.go:379: UpdatingPlatformMachineTemplate=False: AsExpected
util.go:379: AutorepairEnabled=False: AsExpected
util.go:379: Ready=True: AsExpected